Testing and Certification: Suction
outlet covers must have been tested
by a nationally recognized testing
laboratory and found to comply with
the latest version of ANSI/ASME
A112.19.8 or its successor standard,
ANSI/APSP-16, the standard for
Suction Fittings For Use in Swimming
Pools, Wading Pools, Spas, and Hot
Tubs.
Fittings: Fittings restrict flow; for best
efficiency use fewest possible fittings
(but at least two (2) suction outlets).
Avoid fittings which could cause an
air trap.
Pool cleaner suction fittings must
conform to applicable International
Association of Plumbing and
Mechanical Officials (IAPMO
®
)
standards.
Listed/certified to the latest
published version of
ANSI/ASME A112.19.8 or
its successor standard,
ANSI/APSP-16.
Anti-entrapment
Cover/Grate or Suction
Fitting, securely-fastened
to Main Drain Sump
Listed/certified to the latest
published version of
ANSI
®
/ASME
®
A112.19.8 or
its successor standard,
ANSI/APSP-16.
Anti-entrapment
Cover/Grate or Suction
Fitting, securely fastened to
Main Drain Sump
At Least
3 Feet
Suction Outlet
(Main Drain)
Suction Outlet
(Main Drain)
Valves permitted only after tee
Pump
No valves between
Tee and Main Drains
Skimmer
SAVE THESE INSTRUCTIONS
Aqualink RS Conversion Kit is ETL Classied to the following standards
UL 1563
CSA C22.2#218.1
Water Velocity: The maximum water
velocity through the suction fitting
or cover for any suction outlet must
be 1.5 feet per second unless the
outlet complies with the latest version
of ANSI/ASME A112.19.8 or its
successor standard, ANSI/APSP-16,
the standard for Suction Fittings For
Use in Swimming Pools, Wading
Pools, Spas, and Hot Tubs. In any
case, do not exceed the suction fitting’s
maximum designed flow rate.
If 100% of the pump’s flow comes from
the main drain system, the maximum
water velocity in the pump suction
hydraulic system must be six (6) feet
per second or less, even if one (1) main
drain (suction outlet) is completely
blocked. The flow through the
remaining main drain(s) must comply
with the latest version of ANSI/ASME
A112.19.8 or its successor standard,
ANSI/APSP-16, the standard for
Suction Fittings For Use in Swimming
Pools, Wading Pools, Spas, and Hot
Tubs.
Jandy
®
AquaLink
®
RS Conversion Kit

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy AquaLink RS Conversion Kit and is the answer not in the manual?

Jandy AquaLink RS Conversion Kit Specifications

General IconGeneral
BrandJandy
ModelAquaLink RS Conversion Kit
CategoryNetwork Hardware
LanguageEnglish

Related product manuals