Routine Maintenance
Hydraulic System
149 149
9811/5700-7
Oil and Filter
Checking the Hydraulic Fluid Level
!MWARNING
Fluid Under Pressure
Fine jets of fluid at high pressure can penetrate the
skin. Keep face and hands well clear of fluid under
pressure and wear protective glasses and gloves.
Hold a piece of cardboard close to suspected leaks
and then inspect the cardboard for signs of fluid. If
fluid penetrates your skin, get medical help
immediately.
INT-3-1-10_3
1 Park the machine on level ground. Set forks on the
ground. Stop the engine. Remove the starter key.
!MCAUTION
If the fluid is cloudy, then water or air has
contaminated the system. This could damage the
hydraulic pump. Contact your JCB Distributor
immediately.
12-5-1-4
2 Look at the fluid level in the sight glass A. The level
should be at the red mark (or above), but not over the
sight glass.
!MCAUTION
Allow the hydraulic fluid temperature to cool before
removing the hydraulic tank filler cap. Open the cap
slowly to prevent oil being forced out of the filler neck.
5-3-4-8
!MCAUTION
Do not run the engine with the hydraulic tank filler cap
removed.
5-3-4-1
3 If necessary, remove the filler cap B. Add
recommended fluid through the filler.
Fig 113.