Monitoring RPM Probes
The RPM information includes the round-trip time, jitter, and standard deviation
values for each configured RPM test on the Services Router. To view these RPM
properties, select Monitor>RPM in the J-Web interface, or enter the following CLI
show command:
show services rpm probe-results
In addition to the RPM statistics for each RPM test, the J-Web interface displays the
round-trip times and cumulative jitter graphically. Figure 11 on page 145 shows sample
graphs for an RPM test.
Figure 11: Sample RPM Graphs
ERROR: Unresolved graphic fileref="s020039.gif" not found in
"\\teamsite1\default\main\TechPubsWorkInProgress\STAGING\images\".
In Figure 11 on page 145, the round-trip time and jitter values are plotted as a function
of the system time. Large spikes in round-trip time or jitter indicate a slower outbound
(egress) or inbound (ingress) time for the probe sent at that particular time.
Table 77 on page 145 summarizes key output fields in RPM displays.
Table 77: Summary of Key RPM Output Fields
Additional InformationValuesField
Currently Running Tests
Click the Graph link to display the graph (if it is not
already displayed) or to update the graph for a particular
test.
Graph
Configured owner name of the RPM test.Owner
Configured name of the RPM test.Test Name
Type of RPM probe configured for the specified test.
Following are valid probe types:
â– 
http-get
â– 
http-get-metadata
â– 
icmp-ping
â– 
icmp-ping-timestamp
â– 
tcp-ping
â– 
udp-ping
Probe Type
IP address or URL of the remote server that is being
probed by the RPM test.
Target
Address
If no source address is configured, the RPM probe
packets use the outgoing interface as the source address,
and the Source Address field is empty.
Explicitly configured source address that is included
in the probe packet headers.
Source
Address
Using the Monitoring Tools â–  145
Chapter 7: Monitoring the Router and Routing Operations

Table of Contents

Other manuals for Juniper J-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper J-Series and is the answer not in the manual?

Juniper J-Series Specifications

General IconGeneral
BrandJuniper
ModelJ-Series
CategoryNetwork Router
LanguageEnglish

Related product manuals