Installing the inverter
Operating Instructions for Powador .-. TL_EN Page 
EN
. Starting up the inverter
DANGER
Lethal voltages are still present in the terminals and cables of the inverter even after the
inverter has been switched o and disconnected.
Severe injuries or death result if the cables and terminals in the inverter are touched.
Only appropriately qualied and authorised electricians may start up the inverter.
FR
Attachment of safety label in accordance with UTE C --
The code of practice UTE C -- requires that, upon connec-
tion to the French low-voltage distribution network, a safety
sticker showing a warning to isolate both power sources when
working on the device must be attached to each inverter.
" Attach the provided safety sticker visibly to the outside of
the inverter housing.
ATTE NTION
Présence de deux
sources de tension
- Réseau de distribution
-Panneux photovoltaïques
Isoler les deux sources
avant toute intervention
.. Switching on the inverter
The inverter has been mounted and electrically installed.
The PV generator supplies a voltage above the congured start voltage.
. Connect the grid voltage using the external circuit breakers.
. Connect the PV generator using DC isolator switch ( ĺ ).
» The inverter begins to operate.
» During the initial start-up: Follow the instructions of the New Connection Wizard.