GB - 8
2.3 Technical data
2.3.1 230 V class
Product description
Inverter size 09 10
Housing size B
Phases 1 3 1 3
Output rated power [kVA] 2.8 4.0
Max. rated motor power [kW] 1.5 2.2
Output rated current [A] 7.0 10
Max. short time current [A] 12.6 18
OC-tripping current [A] 15.1 21
Input rated current [A ] 14 9.8 20 14
Max. permissible mains fuse (inert) [A] 20 16 25 20
Rated switching frequency [kHz] 4 4
Max. switching frequency [kHz] 8 8
Power loss at nominal operating [W] 59 85
Input rated voltage [V AC] 230 (UL:200…240)
Input voltage range U
mains [V AC] 180…264 ±0
Mains forms TN, TT, IT
2)
, Delta
3)
Mains frequency [Hz] 50…60 ±2
Output voltage [V] 3 x 0…U
mains
Output frequency [Hz] 0…400
Min. motor line cross section [mm
2
] 1.5 2.5
Max. motor line length (shielded) [m]
30 at limit value class C2
10 at limit value class C1
With intergrated braking transistor
Typically braking resistor [Ω] 100 68
Maximal braking current [A] 9.5 12
Leakage current with internal lter (at nOP) [mA] 6
2)insulatingresistanceatmainsformIT=2MΩ
3) on inquiry
Site altitude maximal 2000 m above sea level. With site altitudes over 1000 m a derating of