Page #103 background image
ANTRIEBSTECHNIK
6
23
KEB COMBIVERT F4-F
Name: Basis
17.09.98
Functional DescriptionAnalog In- and Outputs
Chapter Section PageDate
© KEB Antriebstechnik, 1998
All Rights reserved
6
X2.14
REF1 ±
X2.15
REF-
internal
X2.16
REF2 ±
X2.17
AUX-
internal
±100%
±10V
±100%
±10V
An.1
Filter
An.3
An.4
An.5
An.9
An.10
An.11
An.2
An.8
ru.22 ru.23
6.2.1 Brief Description
6.2 Analog In- and Outputs
The KEB COMBIVERT F4-F incorporates one differential voltage input for setpoint
setting (REF1 ±), one programmable differential voltage input (REF2 ±) and two
programmable analog outputs (A1 / A2). Depending on the analog input or output
signal function, offsett and gain can be adjusted.
6.2.2 Analog Inputs
The analog inputs of an digital filter are smoothed by means of averaging. The digital
signals are now available for the characteric amplifiers. In the characteristic amplifier
the input signals can be influenced in X- and Y-direction as well as in the gain. To
avoid voltage fluctuation and ripple voltages around the zero point the analog signal
can be suppressed up to 10 % around the zero point.
Fig. 6.2.1 Diagram of analog inputs
Displays

Table of Contents

Other manuals for KEB COMBIVERT F4-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F4-F and is the answer not in the manual?

KEB COMBIVERT F4-F Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F4-F
CategoryLifting Systems
LanguageEnglish