Page #202 background imageLoading...
Page #202 background image
6 9
KEB COMBIVERT F4-F
10
Name: Basis
09.08.00
Chapter
Section
Page Date
© KEB Antriebstechnik, 1999
All Rights reserved
Functional Description Encoder Interface
dr.25 2419h ✔ - ✔ 256 10000 1 2500 increments / revolution
dr.28 241Ch ✔ - ✔ 0 1 1 0 1 only for sine / cosine encoder
dr.29 241Dh ✔ - ✔ 0110-
dr.30 241Eh ✔ - ✔ 256 10000 1 2500 increments / revolution
dr.31 241Fh ✔ -- 0 13 1 0 -
dr.32 2420h ✔ -- 0 1 1 0 -
dr.33 2421h ✔ -- 0 1 1 0 -
dr.34 2422h ✔ - ✔ 0110-
dr.39 2427h ✔ - ✔ 0 1 1 1 1 = incremental encoder input
dr.40 2428h ✔ - ✔ 0513-
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
6.9.7 Used Parameters
6.9.6 Power Supply
of Encoder
18 V
X4 /
15 pol.
SNT
X2
13
Step
Down
X5
5 V
0 V
15 V
X4 /
15 pol.
SNT
X2
13
Step
Down
X5
Step
Down
ExtGND
GND
5 V
0 V
18 V
5 V
23
11
Fig. 6.9.6 Power supply
up to housing size E as of housing size G
Generally applicable statement with regard to the power supply:
The internal 15V or 18V power supply at X4 and X5 can be loaded altogether with max.
110mA. If higher currents are required; an external voltage can be used.
The 5V-power supply is loadable with altogether 300mA

Table of Contents

Other manuals for KEB COMBIVERT F4-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F4-F and is the answer not in the manual?

KEB COMBIVERT F4-F Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F4-F
CategoryLifting Systems
LanguageEnglish