Parameter Tables
85
ANTRIEBSTECHNIK
6.13 In-Parameter
Size No. Name Adr.
(hex)
P E ro Res. Lower
Limit
Upper
Limit
Default
Value
Unit
In 0 Inverter Type 2C00
table
In 1 Rated Inverter Current 2C01
0,1 0 370,0 A
In 2 Max. Output Frequency 2C02
0,125 0 409,5875 409,5875 Hz
In 3 Max. Carrier Frequency 2C03
10 16 4kHz
In 4 Software - Version 2C04
0,1 b100
In 5 Software Date 2C05
0,1
In 6 Configfile-No. 2C06
1 0 255 46
In 7 Serial No. (Date) 2C07
1 0 65535 0
In 8 Serial No. (Counter) 2C08
1 0 65535 0
In 9 Serial No. (AB-No. high) 2C09
1 0 65535 0
In 10 Serial No. (AB-No. low) 2C0A
1 0 65535 0
In 11 Customer Number
(high)
2C0B
1 0 65535 0
In 12 Customer Number (low) 2C0C
1 0 65535 0
In 13 QS-Number 2C0D
1 0 255 0
In 40 Last Error 2C28
10 63 0
In 41 Error Counter OC 2C29
1 0 255 0
In 42 Error Counter OL 2C2A
1 0 255 0
In 43 Error Counter OP 2C2B
1 0 255 0
In 44 Error Counter OH 2C2C
1 0 255 0