EN
Press the (MENU) button quickly to
quit the menu.
Press the (UP) or (DOWN) but-
tons to scroll through the functions to
modify other parameters.
Press the
(MENU) button for more than 1
second (LONG PRESS) to save the modied
value. The value stops ashing. Alternatively,
press the
(MENU) button QUICKLY to
quit the function without saving.
auto close
ready
BASIC PARAMETERS CT10324
CT10324 OLD CT10224 DESCRIPTION DEFAULT MIN MAX UNIT
1
auto close
TCL
Automatic reclosure time (0 = o󰀨) 0 0 900 s
2
photo close
ttr
Reclosing time after transit on PH1
(0 = o󰀨)
0 0 30 s
3
react time
SEI
Force on obstacles
0 = Maximum impact force
10 = Minimum impact force
3 0 10
4
open speed
SFO
Motor speed during opening
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4 1 5
5
sl-op speed
SSO
Motor speed during opening deceleration phase
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
1 1 5*
6
close speed
SFC
Motor speed during closing
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4 1 5
7
sl-cl speed
SSC
Motor speed during closing deceleration phase
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
1 1 5*
8
SBS setup
SBS
STEP BY STEP or SBS conguration:
0 = Normal (AP-ST-CH-ST-AP-ST…)
1 = Alternate STOP (AP-ST-CH-AP-ST-CH…)
2 = Alternate (AP-CH-AP-CH…)
3 = Apartment block – timer (set
AUTO CLOSE
≠ 0)
4 = Apartment block with immediate reclosure
0 0 4
9
STOP TWO
ST2
Additional stop/edge input:
0 = disabled
1 = PAR input becomes STOP NO
2 = PAR input becomes STOP NC
3 = PAR input becomes EDGE NC in open
4 = PAR input becomes EDGE 8K2 in open
5 = PAR input becomes EDGE 4K1 in open
Attention: to activate EDGE2 the parameter TYPE
EDGE must be 0 (EDGE1 only when closing)
Attention: EDGE2 is connected as “Opening
Edge” and will be considerated if it is engaged
during opening. It will react with a brief reversal of
the gate to clear the obstacle.
Attention: deactivatin safety with DIP SWITCH
has no e󰀨ect on this input
0 0 5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Key Automation CT10324 and is the answer not in the manual?

Key Automation CT10324 Specifications

General IconGeneral
BrandKey Automation
ModelCT10324
CategoryControl Unit
LanguageEnglish

Related product manuals