Engine Troubleshooting (see Table26Table33)
Table 26 Fault of Alarm System
Fault symptom
Cause
Remedy
Oil Alarm
.Low oil level
.Oil filter is blocked
Add oil
Replace oil filter element
Temperature
indicator lamp of
cooling water
.Low cooling water level in
radiator
.Dirty radiator element
3.Cooling water leak, cooling
water pipe is polluted
4. Fan, Water pump
transmission V belt is loosening.
.Fault cooling water pump
Add cooling water
Clean radiator element
Check the leakage part of cooling water,
clean or replace cooling water pipe
Tighten or replace
Repair or replace water pump
Charging indicator
lamp
.Fault battery
.Fault wiring
.Fault AC alternator
Check electrolyte, and recharge or
replace battery
Check, repair or replace
Repair or replace alternator