1.
Remove
nut (2) of breather assembly (1) on the top of the
fuel tank.
Use a tool when the nuts are so tight to remove.
2.
Remove cover (3).
3.
Remove dirt sticking to breather element (4).
4.
Clean in clean diesel fuel or flushing oil.
5.
Install cover (3) and nut (2).
In order not to damage the threaded portion of nut, tighten
nut (2) by hand until it is seated. Then tighten it 15 to 30 °
by using a tool.
METHOD FOR REPLACING DOOR DAMPER
Measure groove depth (A) of door damper rubber (1).
When groove depth (A) decreases to 2 mm or
less, replace the
damper.
The damper is installed at top and bottom, 2 pieces each on
the R.H. and L.H. doors.
METHOD FOR LUBRICATING DOOR HINGE
Perform this when the door creaks when it opens or closes.
1.
Supply spray lubricant through the bushing slit of the
hinge.
2.
If the bushing is worn, replace the hinge.
MAINTENANCE MAINTENANCE PROCEDURE