MAINTENANCE
SERVICE PROCEDURE
CHANGE OIL IN FINAL DRIVE CASE
WARNING
The parts and oil are at high temperature after the engine is stopped, and may cause serious burns. Wait for the temperature
to go down before starting the operation.
If there is still pressure remaining inside the case, the oil or plug may fly out. Turn the plug slowly to release the pressure, then
remove it carefully.
Refill capacity: 13 liters (3.43 US gal) for each (left and right)
1.
Stop the machine so that casting line (1) is horizontal and drain
plug (P) is at the bottom.
2.
Remove drain plug (P), drain the oil, then tighten the plug
again.
3. Add oil through the hole for plug (G) to the specified level.
4.
After adding oil, check that the oil is at the specified level. See
"CHECK OIL LEVEL IN FINAL DRIVE CASE, ADD OIL
(PAGE 4-44)".
CHANGE OIL IN DIFFERENTIAL CASE
WARNING
The parts and oil are at high temperature after the engine is stopped, and may cause serious burns. Wait for the temperature
to go down before starting the operation.
If there is still pressure remaining inside the case, the oil or plug may fly out. Turn the plug slowly to release the pressure, then
remove it carefully.
Refill capacity: 45 liters (11.88 US gal)
1.
Remove drain plug (P), drain the oil, then tighten the plug
again.
2.
Add oil through the hole for plug (G) to the specified level.
3.
After adding oil, check that the oil is at the specified level. See
"CHECK OIL LEVEL IN DIFFERENTIAL CASE, ADD OIL
(PAGE 4-44)".
4 - 72