39
Setting
Selecting Color Space
See below table for available color space.
* Factory default setting :L
v
xy
Color Space
LCD Screen
Display Description
(When Index is selected for display format)
L
v
xy *1
MEAS SNGL
UC00
SPD
N
r
m
Ob
s
2
˚
SYNC
No n
ND
No n
BL
on
LEN
S t d
cd
m
2
Lv
34 . 22
0 . 3958
0 . 4060
x
y
T01
MEAS SNGL
UC00
SPD
N
r
m
Ob
s
2
˚
SYNC
No n
ND
No n
BL
on
LEN
S t d
cd
m
2
Lv
3 . 4221E+1
0 . 3958
0 . 4060
x
y
T01
Displays and outputs in
luminance L
v
and
chromaticity coordinates
x,y.
L
v
u’v’ *1
MEAS SNGL
UC00
SPD
N
r
m
Ob
s
2
˚
SYNC
No n
ND
No n
BL
on
LEN
S t d
cd
m
2
Lv
34 . 22
0 . 2236
0 . 5161
u
v
T01
MEAS SNGL
UC00
SPD
N
r
m
Ob
s
2
˚
SYNC
No n
ND
No n
BL
on
LEN
S t d
Lv
0 . 2236
0 . 5161
u
v
T01
cd
m
2
3 . 4221E+1
Displays and outputs in
luminance L
v
and u’v
chromaticity diagram
(CIE 1976 UCS
chromaticity diagram)
coordinates u’, v.
L
v
T ∆uv
MEAS SNGL
UC00
SPD
N
r
m
Ob
s
2
˚
SYNC
No n
ND
No n
BL
on
LEN
S t d
cd
m
2
Lv
34 . 22
3829K
+0. 009
T
duv
T01
MEAS SNGL
UC00
SPD
N
r
m
Ob
s
2
˚
SYNC
No n
ND
No n
BL
on
LEN
S t d
Lv
3829K
+0. 009
T
duv
T01
cd
m
2
3 . 4221E+1
Displays and outputs in
luminance L
v
, correlated
color temperature T and
color difference from
blackbody locus uv.
XYZ
MEAS SNGL
UC00
SPD
N
r
m
Ob
s
2
˚
SYNC
No n
ND
No n
BL
on
LEN
S t d
X
33 . 36
34 . 22
16 . 71
Y
Z
T01
MEAS SNGL
UC00
SPD
N
r
m
Ob
s
2
˚
SYNC
No n
ND
No n
BL
on
LEN
S t d
X
3 . 3365E+1
3 . 4221E+1
1 . 6709E+1
Y
Z
T01
Displays and outputs in
tristimulus values X, Y,
Z.
Dominant
wavelength/
Excitation purity
*2
MEAS SNGL
UC00
SPD
N
r
m
Ob
s
2
˚
SYNC
No n
ND
No n
BL
on
LEN
S t d
λ
d
+576 . 220n
m
0 . 407%
Pe
T01
Displays and outputs in
dominant wavelength λd
and excitation purity P
e
.
Spectral graph
MEAS SNGL
UC00
SPD
N
r
m
Ob
s
2
˚
SYNC
No n
ND
No n
BL
on
LEN
S t d
38 0
380 n
m
1 . 3118 E
-
5
78 0
T01
Displays or outputs
spectral radiance L
e
(λ)
in the spectral waveform

Table of Contents

Other manuals for Konica Minolta CS-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Konica Minolta CS-2000 and is the answer not in the manual?

Konica Minolta CS-2000 Specifications

General IconGeneral
BrandKonica Minolta
ModelCS-2000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals