Pos: 29.34.11 / BA/Wartung/Mä hwerke/Messerschr aub / Mess erschnellverschlus s/Messerschr aubverschluss Haltebolzen 12 mm AM @ 7 0\mod_13051 77453579_78. docx @ 63553 3 @ 3 @ 1
10.10.2 Blade Screw Connection
DANGER! - Insufficient thickness of material on the retaining bolts.
Effect: Danger to life or serious injuries.
Every time a blade is changed, check the thickness of the holding bolts material.
Damage or worn retaining bolts must always be replaced by sets on each cutting
disc/blade drum!
The material thickness of the retaining bolts must not be less than 12 mm at the weakest
point.
Fig.
31
Pos: 29.34.12 / BA/Wartung/Mä hwerke/Messerschr aub / Mess erschnellverschlus s/Messersch nellverschluss H altebolzen 9 mm AM @ 70\mod_ 1305178072510_ 78.docx @ 6 35701 @ 3 @ 1
10.10.3 Blade Quick-Fit Device
Fig.
32
Pos: 29.34.13 / Layout Modul e /---------------Seitenumbruch---------------- @ 0\mod_1196 175311226_0.do cx @ 4165 @ @ 1