G-19
GL6000, GL7000, GL9000, GL11000, WSM
G GENERAL
[6] CHECK POINT OF EVERY 300 HOURS
Checking Generator’s Brush Wear
1. Check to see if the brush has worn to more than 1/2 below the
standard dimensions.
2. If wear exceeds the allowable limit, replace.
W1037215
Checking Generator’s Slip-ring
1. Check to see if there is no unusual wear and surface roughness.
[GL6000, GL7000]
[GL9000, GL11000]
W1046346
[7] CHECK POINT OF EVERY 400 HOURS
Changing Fuel Filter Element
1. Close the fuel valve (1).
2. Remove the fuel filter element (2).
3. Install the new fuel filter element, screwing it in by hand.
NOTE
Check for fuel leak after replaced it.
W1052658
Brush length (Stretch out
of the Holder)
Standard
length
All model
15.0 mm
0.59 in.
Allowable
limit
GL6000,
GL7000
4.5 mm
0.18 in.
GL9000,
GL11000
7.5 mm
0.30 in.
H : Brush Length
Slip-ring O.D.
Factory spec.
49.7 mm
1.96 in.
Correction limit
47.5 mm
1.87 in.
Slip-ring O.D.
Factory spec.
64.0 mm
2.52 in.
Correction limit
62.5 mm
2.46 in.
(1) Slip-ring
(1) Fuel Valve (2) Fuel Filter Element
KiSC issued 05, 2015 A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota GL6000 and is the answer not in the manual?

Kubota GL6000 Specifications

General IconGeneral
BrandKubota
ModelGL6000
CategoryPortable Generator
LanguageEnglish

Related product manuals