[12] CHECK POINT OF EVERY 1 YEAR
Changing Air Cleaner Element
1. Remove the air cleaner element.
2. Install the new air cleaner element.
NOTE
The air cleaner uses a dry element. Never apply oil to it
Be sure to refit the dust cup with arrow (on the rear)
upright. If the dust cup is improperly fitted, dust passes by
the dust cup and directly adheres to the element.
Do not run the engine with filter element removed.
Change the element once a year or every 6th cleaning.
W1019006
Checking Damage in Electric wiring and Loose Connections
1. Check the state of the wiring harness and if it is abnormal,
exchange it.
2. Check the connector's loosening and if the connector is loose,
connect it firmly.
W1020554
[13] CHECK POINT OF EVERY 2 YEARS
Changing Coolant (L.L.C.)
CAUTION
Do not remove the radiator cap when the engine is hot. Then
loosen cap slightly to the stop to relieve any excess
pressure before removing cap completely.
1. Stop the engine and let cool down.
2. To drain the coolant, open the water drain plug (2), and remove
radiator cap (1). The radiator cap must be removed to completely
drain the coolant.
3. After all coolant is drained, close the water drain plug (2).
4. Fill with clean water and anti-freeze until the coolant level is just
below the port.
Install the radiator cap securely.
5. Fill with coolant up to “FULL” mark on the recovery tank.
6. Start and operate the engine for few minutes.
7. Stop the engine, remove the key and let cool.
8. Check coolant level of recovery tank and add coolant if
necessary.
IMPORTANT
Do not start engine without coolant.
Use clean, fresh water and anti-freeze to fill the radiator.
When the anti-freeze is mixed with water, the anti-freeze
mixing ratio must be less than 50 %.
Securely tighten radiator cap. If the cap is loose or
improperly fitted, water may leak out and the engine could
overheat.
Refer to "4. LUBRICANTS, FUEL AND COOLANT" (G-9).
W1020090
(1) Radiator Cap (2) Water Drain Plug
KiSC issued 05, 2015 A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota GL6000 and is the answer not in the manual?

Kubota GL6000 Specifications

General IconGeneral
BrandKubota
ModelGL6000
CategoryPortable Generator
LanguageEnglish

Related product manuals