EasyManuals Logo

Kubota M108DC User Manual

Kubota M108DC
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #101 background imageLoading...
Page #101 background image
81PERIODIC SERVICE
1. To slow charge the battery, connect the battery
positive terminal to the charger positive terminal and
the negative to the negative, then recharge in the
standard fashion.
2. A boost charge is only for emergencies. It will partially
charge the battery at a high rate and in a short time.
When using a boost-charged battery, it is necessary to
recharge the battery as early as possible.
Failure to do this will shorten the battery's service life.
3. The battery is charged if the indicator display turns
green from black.
4. When exchanging an old battery for a new one, use
battery of equal specification shown in table 1.
Table 1
C Direction for Storage
1. When storing the tractor for long periods of time,
remove the battery from tractor, adjust the electrolyte
to the proper level and store in a dry place out of direct
sunlight.
2. The battery self-discharges while it is stored.
Recharge it once every three months in hot seasons
and once every six months in cold seasons.
A In checking and refilling the battery, be careful not to
spill battery fluid. Spilt battery fluid may affect the
engine controller (ECU) located below the battery,
resulting in damage.
BCleaning Air Cleaner Primary Element
1. Remove the air cleaner cover and primary element.
2. Clean the primary element:
(1) When dry dust adheres to the element, blow
compressed air from the inside, turning the
element. Pressure of compressed air must be
under 205 kPa (2.1 kgf/cm , 30 psi).
(2) When carbon or oil adheres to the element, soak
the element in detergent for 15 minutes then wash
it several times in water, rinse with clean water
and dry it naturally. After element is fully dried,
inspect inside of the element with a light and
check if it is damaged or not.
3. Replace air cleaner primary element:
Once yearly or after every sixth cleaning, whichever
comes first.
A Check to see if the evacuator valve is blocked with
dust.
(1) Battery
Battery Type Volts (V)
Capacity at
5H.R(A.H)
GP31
(105E41R)
12 85.3
Reserve
Capacity
(min)
Cold
Cranking
Amps
Normal
Charging
Rate (A)
160 900 11
(1) Secondary (safety) element
(2) Primary element
(3) Evacuator valve
(4) Cover

Table of Contents

Other manuals for Kubota M108DC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota M108DC and is the answer not in the manual?

Kubota M108DC Specifications

General IconGeneral
BrandKubota
ModelM108DC
CategoryTractor
LanguageEnglish

Related product manuals