2PK/2PL/2PM/2PN-5
1-3-39
U411 Auto Adj Scn
Description
Uses a specified original and automatically adjusts the following items in the scanner and the DP
scanning sections.
Scanner section: Original size magnification, leading edge timing, center line, input gamma, input
gamma in monochrome mode and matrix.
DP scanning section: Original size magnification, leading edge timing, center line.
Purpose
To perform automatic adjustment of various items in the scanner and the DP scanning sections.
Method
1. Press the start key.
2. Select the item. The screen for executing is displayed.
Item No. Description
Display Description
Original to be used
for adjustment (P/N)
Table Automatic adjustment in the scanner sec-
tion.
Equal magnification (sub scanning direc-
tion), leading edge timing, center line, input
gamma, input gamma in monochrome
mode and matrix, chromatic aberration.
302NM94340
DP Automatic adjustment in the DP scanning
section.
Original size magnification, leading edge
timing, center line.
302NM94330
All Performs automatic adjustment in the DP
scanning section following automatic
adjustment in the scanner section.
302NM94340
302NM94330
Target Set-up for obtaining the target value 302NM94340
302NM94330