29
Technical Data
Sprinter 150/150M/250M - 1.0.0en
EN
DE
FR
ES
NO
SV
FI
DA
IT
PT
NL
13. Technical Data
Height measurements Standard deviation per km double run (ISO 17123-2):
Electronic measurement with Sprinter aluminum barcode staff:
1.0 mm (Sprinter 250M)
1.5 mm (Sprinter 150/150M)
Optical measurement with standard aluminum E-scale/Numeral staff: 2.5 mm
Standard Deviation for single staff reading: 0.6 mm (electronic) and 1.2 mm (optical) at 30m
Distance Accuracy
(Standard Deviation)
10 mm for D<= 10 m
Distance in m x 0.001 for D>10 m
Range Distance measuring range for electronic measurements with standard aluminum barcode staff: 2 m to
100 m.
Optical - Shortest focusing
distance
50 cm
Measuring time single
measure (Electronic)
Typically 3 seconds and less in normal daylight condition; needs longer measuring time in uniform dim
light condition (20 lux).
Circular Bubble Circular Bubble Sensitivity: 10'/2 mm
Compensator Magnet damped pendulum compensator with electronic range monitoring
Tilt Warning Range (Electronically): ± 10'
Compensator range (Mechanically): ± 10'
Setting accuracy: 0.8" max. (Standard Deviation)
Magnetic field sensitivity: < 10"
(Line-of-sight difference in horizontal constant magnetic field at a field strength of up 5 Gauss)
RS232 Port* For RS232 cable connection to external battery and communication to PC / data collector.
Phone Jab Port* For USB cable connection to communication to PC.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Leica Sprinter 150 and is the answer not in the manual?

Leica Sprinter 150 Specifications

General IconGeneral
BrandLeica
ModelSprinter 150
CategoryLaser Level
LanguageEnglish