EasyManuals Logo
Home>Lennox>Controller>PRODIGY2.0

Lennox PRODIGY2.0 User Manual

Lennox PRODIGY2.0
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
106
Table 59. Menu Interface (Level 1 - SETTINGS)
NOTE: AVAILABLE MENU OPTIONS ARE DEPENDENT ON HARDWARE CONFIGURATION. USE THE ADJUST AND SET VALUES ARROWS
TO SCROLL UP OR DOWN FOR SELECTION OPTIONS.
Level 2 Level 7Level 6Level 5Level 4Level 3
RTU OPTION
DEHUMIDIFIER
MODE
= BLOWER,
OCCUPIED
= LOCAL SENSOR,
NETWORK SENSOR
DEHUMIDIFIER DEHUMID SETPOINT = X.XX %
DEHUMIDIFIER DEHUMID DEADBAND = X.X %
= REHEAT DI4
= NO CONDITIONS
= LOCAL SENSOR
OR NETWORK
SENSOR
DEHUMIDIFIER DEHUMID SETPOINT = X.XX %
DEHUMIDIFIER DEHUMID DEADBAND = X.X %
= REHEAT DI4
= REPORT RH ONLY = LOCAL SENSOR OR NETWORK SENSOR
= DISABLED
= BLWR, OCC,
PREV COOL
= LOCAL SENSOR
OR NETWORK
SENSOR
DEHUMIDIFIER DEHUMID SETPOINT = X.XX %
DEHUMIDIFIER DEHUMID DEADBAND = X.X %
= REHEAT DI4
= PREVIOUS
COOLING
= LOCAL SENSOR,
OR NETWORK
SENSOR
DEHUMIDIFIER DEHUMID SETPOINT = X.XX %
DEHUMIDIFIER DEHUMID DEADBAND = X.X %
= REHEAT DI4
EDIT PARAMETER ENTER DATA ID =
INSTALL
NEW UNIT SETUP
SEE TABLE 57 ON PAGE 98 FOR SETUP PROMPTS FOR NEW SETUP. (THIS IS THE SAME AS
SETUP > INSTALL DEHUMIDIFIER MODE PORTION OF THE WIZARD.)
INSTALL NEW M3
CLEAR ALL CONFIG=YES OR NO. IF YES IS SELECTED. ARE YOU SURE?=YES OR NO. SEE
TABLE 57 ON PAGE 98 FOR SETUP PROMPTS FOR NEW M3 UNIT CONTROLLER.
NOTE: PARAMETERS AVAILABLE ARE DEPENDENT ON MODEL NUMBER AND CONFIGURATION ID 1 AND 2 SETTINGS. IN ORDER FOR
ANY CHANGE TO THE SYSTEM TO TAKE AFFECT, BACK COMPLETELY OUT OF THE CURRENT LOCATION TO THE MAIN MENU OR
STATUS SCREEN.
GENERAL
LANGUAGE = ENGLISH, FRANCAIS OR ESPANOL
DATE/TIME
DAY, MONTH, YEAR HOURS, MINUTES AND SECONDS
NOTE: HOURS IN 24 HOUR CLOCK FORMAT (MILITARY)
DISPLAY UNITS F/C = FAHRENHEIT OR CELSIUS
RTU DESCRIPTION ENTER A 18 POSITION ALPHA / NUMERIC NAME
CATALOG NUMBER = LOCATED ON UNIT NAMEPLATE.
MODEL NUMBER = LOCATED ON UNIT NAMEPLATE.
SERIAL NUMBER = LOCATED ON UNIT NAMEPLATE.
CONFIGURATION ID
1
= WHITE STICKER TITLED “ORIGINAL FACTORY UNIT CONFIGURATION” LOCATED ON THE
RIGHT SIDE OF THE CONTROL BOX NEAR THE M3 CONTROLLER.
CONFIGURATION ID
2
NOTE: PARAMETERS AVAILABLE ARE DEPENDENT ON MODEL NUMBER AND CONFIGURATION ID 1 AND 2 SETTINGS. IN ORDER FOR
ANY CHANGE TO THE SYSTEM TO TAKE AFFECT, BACK COMPLETELY OUT OF THE CURRENT LOCATION TO THE MAIN MENU OR
STATUS SCREEN.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox PRODIGY2.0 and is the answer not in the manual?

Lennox PRODIGY2.0 Specifications

General IconGeneral
BrandLennox
ModelPRODIGY2.0
CategoryController
LanguageEnglish

Related product manuals