Technical data
General data and operating conditions
3
84
EDK82MV371 DE/EN/FR 7.0
3 Technical data
General data and operating conditions
Conformity and approval
Conformity
CE
2006/95/EC Low−Voltage Directive
2004/108/EG EMC Directive
Approval
UL UL 508C Underwriter Laboratories (File No. E132659)
Power Conversion Equipment
CSA 22.2 No. 14
GOST−R 51321.1−2000 No. POCC DE.AN30.Bo8845
51321.3−99
Protection of persons and equipment
Type of protection IEC/EN60529
NEMA 250 / UL50
IP55 without protective cap on the AIF interface,
protection against accidental contact according to
type 12
IEC/EN60529
NEMA 250 / UL50
IP65 with protection cover on the AIF interface,
protection against accidental contact according to type 4
Earth leakage current IEC/EN 61800−5−1 > 3.5 mA AC
> 10 mA DC
Observe regulations and
safety instructions!
Insulation of control
circuits
IEC/EN 61800−5−1 Safe mains isolation by double (reinforced) insulation
Insulation strength IEC/EN 61800−5−1
Overvoltage category III for site altitude £ 2000 m
Overvoltage category II for site altitude > 2000 m
Protective measures Short circuit, short to earth (protected against short to earth during operation,
limited protection against short to earth on powerup), overvoltage, motor
stalling, motor overtemperature (input for PTC or thermal contact, I
2
t