Appendix
11-10
BA9300SU EN 2.1
11.2.4 Digital frequency bus - slave - drive
The most important settings (short setup)
Tip!
The following codes are contained in the menu: ”Short Setup / DF slave bus” of the Module 9371
BB or in the menu ”Short commissioning / Digital frequency slave line” of Global Drive Control or
LEMOC 2.
Input motor type (contains all nameplate data of the motor)
C0173 xxx Enter UG limit (mains voltage)
C0086 xxx Enter LENZE motor type
Enter maximum motor current
C0022 xxxA Determine Imax
Enter controller configuration
C0005 6000 Select digital frequency bus - slave
C0025 xxx Enter feedback system
Speed setpoint settings
C0011 xxx rpm Determine max. speed
C0032 xxx Gearbox factor numerator
C0033 xxx Gearbox factor denominator
C0425 xxx Adapt encoder constant to the master
Application parameters
C0070 xxx Vp n controller
C0071 xxx Tn n-controller
C0254 xxx Gain of the phase controller
Save parameters
C0003 xxx Save all parameters