Codes
Communication−relevant Lenze codes
10
71
EDS82ZAFPC010 EN 4.0
10.2 Communication−relevant Lenze codes
C1509: Bus device addressing
Code Subcode Index
Possible settings
Data type
Lenze Selection
C1509 23066
d
=
5A1A
h
3 3 [1] 126 FIX32
This code serves to set the bus device address. The setting in this code is only effective if the
DIP switches S1 ... S7 are set to OFF.
Note!
ƒ The bus device addresses of networked controllers must differ from each
other.
ƒ Switch off the voltage supply of the function module and the controller, and
then switch it on again to activate the changed settings.