Communication in SDI-12 mode
46 Snow depth sensor SHM 31, V2.1
10.7. Additional measuring commands
With the additional measuring commands
aM1! … aM2!
aMC1! … aMC2! (M command, data transfer with CRC)
aC1! … aC2!
aCC1! … aCC2! (C command, data transfer with CRC)
additional measured values can be retrieved.
As with the basic data, a maximum of 9 measured values can be retrieved with an M command;
20 places are available with C commands.
The buffer assignment documented below is therefore structured such that buffers D0 and D1 are
allocated to the respective M command. If more measured values are available for the sensor
type, the buffers D2 to D4, if applicable, are also allocated to the corresponding C command.
M1 / C1 Angles M: 6 values C: 6 values
M2 / C2 Flags M: 7 values C: 7 values
Tilt angle reference (cur)
Table 7: SDI-12, additional values (M1 / C1: Angles) configured in metric or in US units
Table 8: SDI-12, additional values (M1 / C2: Flags) configured in metric units. The fog flag is not calculated at present.