Communication in SDI-12 mode
52 Snow depth sensor SHM 31, V2.1
0XPLMI+5000<CR><LF>
10.12.2. Setting the parameter setting
Command: aXPccc<+/->nnn!
aXPccc<+/->fff.f!
ccc: Three-character parameter code; see table
nnn, fff.f: Parameter value to be set, number of digits as required
The entry can be made both as an integer and as a floating point number, regardless of the
parameter’s number type, and the value is rounded if necessary.
Response: aXPccc<+/->nnn<CR><LF> for integer
par
ameters
nnn: New parameter
aXPccc<+/->ff.f<CR><LF> for
f
loating
poi
nt
p
arameters
ff.f: New parameter
The number of nnn or fff digits is variable according to the parameter value.
aXP_invalid<CR><LF> if the new parameter value is beyond
the limits
aXP_invalid-<CR><LF> parameter without a leading sign, but with
a negative number set
aX_noCmd<CR><LF> in case of unknown parameter code ccc
Example: Setting the laser measurement interval, SHM 31-UMB with SDI-12 ID ‘0’
0XPLMI+2500! or 0XPLMI+2500.0!
0XPLMI+2500<CR><LF>
Value limts (factory
settings in bold characters)
Enable external switching of
heating
Heating defrost after power on
Time constant for suppression of
short term depth changes
Maximum accepted change of
snow depth per interval
-20000.0 … 20.0 … 20000.0
Laser measurement interval
Table 11: SDI-12, setting the parameter settings