Filter cycles
the MODE button the spa works properly and
safely at 37.5 °C. In this mode, all user buttons
are active. However, to be able to benefit from
the unique possibilities of this function, it is
important to set filter cycles.
Pre-set filter cycles (430/432 series)
Your operating system functions on the basis of
two filter cycles. The first cycle starts six minutes
after you connect the spa to the power supply.
The second filter cycle starts 12 hours later.
The cycles are factory-set for a filtration cycle
of 3 hours. For example: The spa is turned on
at 08.00 hours:
Filter cycle 1 runs from 08.06 to 11.06 hours.
Filter cycle 2 runs from 20.06 to 23.06 hours.
At the start of each filter cycle, pump 1 is
activated at low speed. If the buttons are set to
Economy mode, the heater is used as required.
The ozonator is activated 60 seconds after the
start of a cycle.
Changing the filter cycles (430/432 series)
The duration of a filter cycle can be set from
one hour per cycle to twelve hours per cycle
and is carried out twice in a 24-hour period.
Therefore, a cycle of 1 hour carried out once
every 12 hours give a total filtration time of
two hours, while a cycle of 12 hours which
is carried out twice a day gives 24 hours of
continuous filtration. The time required to
filter your spa depends on the level of use
and the condition of the surroundings.
The spa filter cycles are also determined
by your personal use.
If you want to change the duration of the
filter cycles, press UP or DOWN and then
MODE. You will now see the following in
the central display:
FIL3
MODE/PROG and the display will show SET
FILTER 1. Each time you press MODE/PROG,
the filter start time, the status of the heater and
the filter stop time are show on the LCD display.
When the filter start or stop times are shown,
you can adjust them by pressing SET UP or SET
DOWN. When the message Set Heat is show,
press SET UP or SET DOWN to turn the
central display ON or OFF. In the ON position,
the spa is heated to the set temperature during
the filter cycles. In the OFF position, the heater
is not activated during the filter cycles.
NOTE:
If you want to use the heater in Economy
mode, the display must show ON. In
Standard mode the heater is always ON.
Standard mode is recommended during
periods of cold weather.
Having set the filter commands, press
MODE/PROG to enter the start and
stop times for the second filter cycle.
Follow the same steps as for Filter 1.
NOTE:
At the start of the second filter cycle, pump 2
is activated to clean the water in the pipes
and to guarantee complete filtration.
The second filter cycle must NOT be left
out during periods of cold weather.
To finish setting the filter cycles, press
MODE/PROG. You will now see the current
water temperature on the LCD display.
Filter cycles (430/432 series)
This function is designed so that by connecting
the spa to a properly earthed supply and pressing