Commissioning and operation
79
Description of acoustic signal transmitter
Warnings and alarms can be reproduced via the acoustic signal transmitter..
Interval signal
tone
Event Meaning
fast actuation of the button Handover of the control console possible
slow
Initialisation of the connected control Handover of the control console is requested
actuation of the button Handover of the control console not possible
Continuous tone Fault alarm of the connected control Alarm
Activate control console
If the control is switched on via the master switch, first all control consoles are initialised.
This is indicated by a slow flashing LED on each control console.
D
D and an unbroken acoustic signal.
During the initialisation
D the control consoles are inactive and
D the vessel cannot be controlled from any control console.
Select control head
Select the control head by actuating the button.
TheLEDs and signal tone stop on all other control consoles.
If the levers are not in the “Neutral“ position, the LEDs continue to flash and the sig
nal tone remains the same.
If necessary, place the lever in the “Neutral" position.
The LEDs now flash quickly and the signal tone is faster.
Extinguish the LEDs by pressing the button again .
The control console is active and the engine can be started.