Maintenance work on the carrier
7.5 Exhaust system with exhaust emission control
25.11.2016
Maintenance manual 3 302 364 en 7 - 33
GMK 4100L-1
7.5 Exhaust system with exhaust emission control
Overview To comply with the exhaust emission regulations, the truck crane may only
be run with the exhaust system with SCR catalytic converter (SCR =
Selective Catalytic Reduction).
The exhaust gas is treated using a DEF system. To do this, AdBlue (DEF)
(Diesel Exhaust Fluid) from the DEF tank is injected into the exhaust system.
The motor output is automatically sharply reduced when there is not
enough AdBlue solution available. Driving with an empty AdBlue tank will
invalidate the truck crane's licence for use on public roads;
à Operating
Instructions
, à Engine manufacturer’s documentation.
AdBlue system
1 AdBlue tank with insulation hood
2 Pu
mp unit
for pumping AdBlue to the dosing unit
on the diesel engine and for pumping
engine coolant for preheating the
AdBlue tank.
4 Tank gauge, AdBlue tank
3 Tank gauge for AdBlue tank,
with warning symbol
8 Diesel engine
with dosing unit for AdBlue (compressed
air supply) and a solenoid valve for
preheating the AdBlue tank using engine
coolant.
6 Injection nozzle
for injecting the AdBlue/compressed
air mixture.
7 Exhaust pipes
9 Exhaust silencer
with SCR catalytic converter

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 4100L-1 and is the answer not in the manual?

Manitowoc Grove GMK 4100L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 4100L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals