Maintenance work on the carrier
7.14 Compressed air system
7 - 94 3 302 364 en Maintenance manual
GMK 4100L-1
25.11.2016
7.14.2 Checking for leaks
• Start up the compressed air system.
• Check for any possible leaks in the compressed air system (connections,
pipes, hose lines and valves).
If damage cannot be rectified immediately or further damage is likely:
• Notify Manitowoc Crane Care or an authorised GROVE dealer or your repair
crew.
G
Risk of accidents due to escaping compressed air.
Never tighten connections when the system is under pressure. Only change
gaskets, pipes and hose lines when the system is depressurised.