Maintenance work on the carrier
7.16 Central lubrication system
25.11.2016
Maintenance manual 3 302 364 en 7 - 115
GMK 4100L-1
7.16 Central lubrication system
7.16.1 Checking the level
Grease, spare
parts, tools
– Filling pump from the tool set.
Prerequisites – The parking brake must be applied.
Checking the level
• Check the level in the grease container (1).
The grease level must be close to the max.
mark and the green lamp (2) must light
(ready for operation).
If it is below the min. mark the grease level
is too low and the red lamp (3) will light.
If the level is too low
• Add more grease; à p. 7 - 116.
s
W
Lubricating
grease
Designation
to DIN 51502
Specification
classification
GROVE part no.
Grease KP - 1K - 50 DIN 51825 03233369