Maintenance work on the superstructure
8.3 Hoists
8 - 10 3 302 364 en Maintenance manual
GMK 4100L-1
25.11.2016
8.3.2 General inspection
• Pay attention to any unusual running noises from the hoists.
• Check the hoists and the connections for leaks. If consumables are
leaking;
à Checking the oil level, p. 8 - 9.
• Check that pipes and hoses are tightly connected and undamaged.
If any damage is found, report it to
Manitowoc Crane Care or an authorised
GROVE dealer or your repair crew.
8.3.3 Checking the hoist brake
Check that the hoist brake is working correctly on the main hoist and the
auxiliary hoist.
• Attach the hook block to the hoist rope, reeved once.
• Lift a load of approx. 7 t ( 15,500 lbs) to approx. 30 cm (1.0 ft) above the
ground.
• Measure the distance to the ground when the load is hanging completely
still.
• Switch the engine off.
If the load has not lowered after approx. 2 minutes, the br
ake is currently
in working order.
If the load lowers, notify
Manitowoc Crane Care or an authorised GROVE
dealer.
W
W

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 4100L-1 and is the answer not in the manual?

Manitowoc Grove GMK 4100L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 4100L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals