Maintenance work on the superstructure
8.6 Hydraulic system
8 - 40 3 302 364 en Maintenance manual
GMK 4100L-1
25.11.2016
Changing oil
filter 1
• Remove the cover (1).
• Remove the cover (2) and pull out the
hydraulic oil filter.
• Place the filter in a receptacle.
• Remove the filter (4) from the filter cage (5).
• Clean the filter cage (5) and insert a
new filter (4).
• Clean the magnetic rods (3).
• Replace any damaged parts,
where necessary.
• Assemble the filter (3) and insert it.
• Replace the cover gasket if necessary.
• Bolt the cover (2) on.
• Attach the cover (1).
O
Risk of environmental damage due to leaking consumables.
Always let consumables drain into suitable receptacles. Wipe up any
consumables tha
t escape.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.
S
Risk of damage to the hydraulic system.
Large amounts of metal particles are a sign of damage in the hydraulic
system.
Have the hydraulic system checked by Manitowoc Crane Care or an
authorised GROVE dealer or your qualified repair crew.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 4100L-1 and is the answer not in the manual?

Manitowoc Grove GMK 4100L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 4100L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals