eikon e2s Service and Repair Manual UL 105
Earth/Insulation test
Check that the following requirements have been met:
The appliance has been disconnected from the power supply and protective measures have been
taken to ensure the power cannot be switched on again.
1.
Connect the mains lead from the appliance to a Portable Appli-
ance Tester.
2.
Connect the earth from the Portable Appliance Tester to the
appliance.
3.
Place the Portable Appliance Tester in an open area, such as the
floor, away from any persons.
Perform a Class 1 test in accordance with tester instructions.
A PASS indicates the oven earthing circuit is functioning cor-
rectly.
If a FAIL is indicated (i.e. unit exceeds maximum limit), remove
the casing of the appliance and check ALL earth connections.
Then repeat the Class 1 test.
WARNING:
Never operate an appliance that has failed this test as it could be
potentially dangerous.
Service Mode: Tests Menu
1.
Enter Service Mode.
For details see "Checking the condition of your appliance".
Select the down arrow to display the individual tests for the
appliance to perform.