eikon e2s Service and Repair Manual UL 22
IMPORTANT
To Service Technicians:
PRECAUTIONS TO BE OBSERVED BEFORE
AND DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE
ENERGY.
a.
Do not operate or allow the oven to be operated with the door open.
b.
Make the following safety checks on all ovens to be serviced before activating the magnetron or
other microwave source, and make repairs as necessary:
1) interlock operation,
2) proper door closing,
3) seal and sealing surfaces (arcing, wear, and other damage),
4) damage to or loosening of hinges and latches,
5) evidence of dropping or abuse.
Before turning on microwave power for any service test or inspection within the microwave gen-
erating compartments, check the magnetron, wave guide or transmission line, and cavity for
proper alignment, integrity and connection.
d.
Any defective or misadjusted components in the interlock, monitor, door seal, and microwave
generation and transmission systems shall be repaired, replaced, or adjusted by procedures
described in this manual before the oven is released to the owner.
e.
A microwave leakage check to verify compliance with the Federal Performance Standard for the
U.S.A. or the Canadian Regulation, HEALTH AND WELFARE, SOR/79 920 for Canada should be
performed on each oven prior to release to the owner.