eikon e2s Service and Repair Manual UL 142
Cavity thermostat (cavity overheat stat)
The thermostat continuously measures the temper-
ature in the cavity and prevents it from overheating.
29
Cavity temperature sensor wire (thermocouple)
entering the cavity
The sensor wire extends between the thermostat
and the interior of the cavity.
30
Some components are earthed at the metal base
plate of the oven.
31
Electromagnetic Compatibility (EMC) Filter (2000W
e2s variant: 2x)
EMC filters reduce the transfer of electromagnetic
noise between the drive (convection fan motor and
motor speed controller) and the mains power supply.
32
The fuses protect the oven from high voltag-
es/currents.
33
Equipotential bonding connection (CE appliances
only)
This is an electrical connection that ensures that the
frames of electrical equipment and any external
conductive components are at an equal (or practi-
cally equal) potential.
Tools required
M5.5 hex socket wrench / nut runner
M7 hex socket wrench / nut runner
M7 hex socket wrench / ring spanner
M8 hex socket wrench / nut runner
Stanley knife (for cutting tape)
Long handled Pozidriv screwdriver PZ1
Long handled Pozidriv screwdriver PZ2
Flat screwdriver or lever
Pliers (or M14 ring spanner)
Two metal pins (length: 10 mm / 0.4 in)
Hammer (for removing pressed screws from a spare magnetron)