Commissioning the oven after service/repair/testing
Complete the following checks after the oven has been serviced/repaired/tested before connecting to
the mains electricity power supply:
All internal electrical connections are correct (see "Electrical circuit diagrams").
2.
All wiring insulation is correct and is not touching any sharp edges.
3.
All grounding connections are electrically and mechanically secure.
4.
All door safety interlocks are secure and mechanically sound.
The door activates all of the door interlock switches and in the correct order.
6.
The door operation is smooth, and the arms run freely in the slots.
7.
The temperature sensor (thermocouple) is correctly connected to the SRB.
8.
The casing is securely refitted with no trapped wires.
Before finishing a service call, recheck the following points:
9.
Run the recommission tests to ensure the oven is functioning correctly and the
touch screen is working.
10.
Microwave emissions are below the permissible limit of 5 mW/cm².
11.
The power output of the oven is checked in accordance with the procedure.
12.
The oven has a correct air gap of 50 mm / 2 inches above.
Air flow should not be restricted.