SETUP AND INSTALLATION MLC165-1 OPERATOR MANUAL
4-6
Published 08-06-19, Control # 237-09_v2
SETUP MODE
To operate in the setup mode, two steps must be performed:
• The desired setup icon (2a or 2b, Figure 4-3
) and the
proper Liftcrane Mast Handling Capacities Chart (1)
must be selected in the RCL/RCI configuration screen.
See the RCL/RCI Manual supplied with the crane for
detailed instructions.
• The appropriate control icon (1 or 2, Figure 4-5
) must be
turned on in the setup function screen of the main
display.
To navigate to the Setup Function screen (Figure 4-5):
1. At the Main Display screen, press the Scroll Up key
or Scroll Down key
to cycle through the screen icons
until the Function icon becomes highlighted with a blue
border.
2. Press the Enter key
. The Function Selection
screen appears.
3. At the Function Selection screen, press the Scroll Up
key
or Scroll Down key to cycle through the
highlighted crane functions until the Wrench Icon
appears at the bottom of the screen.
4. Press the Enter key
. The Setup Function screen
appears.
To change a field (Figure 4-5):
1. Press the Scroll Up key
or Scroll Down key to
cycle through the screen fields until the desired field
becomes highlighted with a blue border.
2. Press the Enter key
. The field becomes highlighted
with a red border.
3. Press the Scroll Up key
or Scroll Down key to
toggle a function on (I) or off (O).
Once the setup mode is on, the icon in Figure 4-4
will appear
in the fault area of the information screen and the fault alarm
will sound with an intermittent tone.
-0.0T
00.0 T
2
+60.0°
8.3 M
0000 AM
00.0 T
142.9 T
4.6 M
Item Description
1 Capacity Chart Box
2a Setup Icon on Jacks
2b Setup Icon on Crawlers
1
2b
Figure 4-3
14COM4102
2a
OR
NOTE The setup functions operate the same,
regardless of which icon is selected