20
CAL 2 CALIBRATION
CAL2 Display Calibrations:
Paddle Wheel Speed Sensor Frequency Setting
Pitot Water Pressure Speed Sensor Input Setting
Pitot Water Pressure Speed Sensor Multiplier
Fuel Tank Calibration
1. Turn ignition key to the on position.
2. Press and hold
and for 3 seconds to bring up the
CAL 1 calibration screen. Press and hold
and again
for 3 seconds to bring up the CAL 2 calibration screen.
NOTE:Press and hold
and for 3 seconds to get out of
the CAL 2 calibration screen.
Cal 2 Start Screen
Press the button to move to the next calibration screen.
Pitot Water Pressure
Sensor Input
Select the pressure input of the
Pitot water pressure sensor on
the engine.
NOTE:The standard speed in-
put on production Mercury Out-
boards is 100 PSI. Certain High
Performance applications may
require a 200 PSI input.
1. Press the
button to select.
0 =No Pitot pressure sensor
1 = 100 PSI
2 = 200 PSI
2. Press the
button to move to the next function.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mercury SmartCraft Systems Monitor and is the answer not in the manual?

Mercury SmartCraft Systems Monitor Specifications

General IconGeneral
BrandMercury
ModelSmartCraft Systems Monitor
CategoryMonitor
LanguageEnglish

Related product manuals