-14-
4.5 Comfort timer setting
If, in the COOL or HEAT mode or Automatic COOL or HEAT mode, the timer is set to ON, the
Comfort Timer functions.
The initial value is 15 minutes. The start time for next operation is determined according to the
relationship between the room temperature (sensor) at the time of setting and the set temperature
(max. 60 minutes).
Notes: (1) The room temp. sensor (Th1) commences operation 5 minutes before the timer is ON,
regardless of the temperature.
(2) In the DRY or Automatic DRY mode, the function does not work.
However, in the Automatic DRY mode, the operation described in (1) commences.
(3) During the comfort reservation operation, the RUN lamp and TIMER lamp light up.
After expiration of the timer, the TIMER lamp goes off.
(Example) HEAT
Detect the temperature difference to compensate the start time of next operation.
15 min 10 min 5 min time set
earlier earlier earlier
● If the difference between the set temperature and room temperature is 4℃, according to the
above table, the correction value is +5 minutes, therefore, the start time of next operation is:
15 minutes earlier + 5 minutes = 20 minutes earlier
Compensation value
Start time of current operation