α2
Simple Application Controllers
Function Blocks 6
6 - 73
3 ) Delayed One Shot sample program
4 ) Delayed One Shot comparison sample program
Setup of the Delayed One Shot Function Block directly from the
α2 Series Controller
1 ) Allocate the input pin to be used for the function block.
2 ) Press the “OK” key with the cursor in the function block. The function block edit screen is
displayed as shown.
3 ) Press the “OK” key to set the Time unit for the random delayed output. Choose either a
10ms, 100ms or 1s time interval using the “ and ” keys to highlight the option and press
the “OK” key when ready.
4 ) Return to the function block edit screen. Using the “Up and Down” keys to highlight the
Setup FB and press the “OK” key.
I01
I02
DOS
O01
I
CL
• Delay Start: ON to OFF (Off to On)*
• Delay Time: 1s
One-Shot Time: 1s
I01
I02
PL
I
• On Delay:
1s(10
×
100ms)
• Off Delay:
0s(0
×
100ms)
SR
S
R
DL
I
CL
OS
O01
OR
From On to Off
(From Off to ON) *
Reset priority
CL
I
1
2
One-Shot Time
<Control time>: 1s(10
×
100ms)
Output Clear Condition: None
B001 : D SO
Time uni
Change No
De l e t e FB
t
Se t up FB
Time uni t
100 sm
10 ms
1s
De l yT mie
OneSh to
B001 : D SO
Cond i itno
a

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi AL2 Series and is the answer not in the manual?

Mitsubishi AL2 Series Specifications

General IconGeneral
ModelAL2 Series
Digital InputsYes
Digital OutputsYes
TypePLC
ManufacturerMitsubishi
Input Voltage100 to 240 VAC or 24 VDC (depending on model)
Output Voltage24V DC
Number of Inputs8 to 64 (depending on model)
Number of Outputs6 to 64 (depending on model)
Programming LanguageLadder Diagram
Communication PortsRS-232, RS-485, Ethernet (depending on model)
Operating Temperature0 to +55°C
Storage Temperature-20°C to 70°C
Humidity10% to 90% (non-condensing)
WeightVaries depending on the model