α2
Simple Application Controllers
Function Blocks 6
6 - 45
2 ) Upper limit < Lower limit
Normal input max. 20Hz
Interrupt input terminal for Al2-4EX max. 1KHz
Clear input pin
Input pin
Count input pin
Current value of
counter
Lower limit: 7
Upper limit: 4
Speed output
value
Output pin
OFF ON
ON
1
2
3
4
5
9
1
2
3
4
5
1
2
3
4
1
8
1
2
3
0
8
045
9
50
Set cycle
ON
Clear input pin
Count input pin
(EI01/EI02 on
AL2-4EX)
Current value of
counter
Speed output
value
Output pin
ON
1
2
3
4
5
10
1
2
3
4
0
8
1
000
10
6
0
ON
6
Set cycle
7
6
5
4
3
2
1
1 scan
time
Processing time
Lower limit: 7
Upper limit: 4
ON

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi AL2 Series and is the answer not in the manual?

Mitsubishi AL2 Series Specifications

General IconGeneral
ModelAL2 Series
Digital InputsYes
Digital OutputsYes
TypePLC
ManufacturerMitsubishi
Input Voltage100 to 240 VAC or 24 VDC (depending on model)
Output Voltage24V DC
Number of Inputs8 to 64 (depending on model)
Number of Outputs6 to 64 (depending on model)
Programming LanguageLadder Diagram
Communication PortsRS-232, RS-485, Ethernet (depending on model)
Operating Temperature0 to +55°C
Storage Temperature-20°C to 70°C
Humidity10% to 90% (non-condensing)
WeightVaries depending on the model