6. BASIC INSTRUCTIONS
6 63
MELSEC-A
Execution The execution conditions of CALL and CALLP are a shown below.
Conditions
When a program uses the PLS and PLF instructions in the subroutine, and when the
ON/OFF time of a subroutine execution designation signal is set shorter than the
scan time, the device designated with (D) of the subroutine PLS and PLF
instructions may sometimes remain turned ON more than 1 scan.
Operation Errors In the following cases, operation error occurs and the PC stops operation.
After the CALL(P) instruction is executed, the END(FEND) instruction has been
executed before executing the RET instruction.
The RET instruction has been executed before executing the CALL(P) instruction.
The label P255 has been called by the CALL(P) instruction.
The JMP instruction was executed to exit from a subroutine before execution of
the RET instruction.
Nesting is of six or more levels.
OFF
ON
Executed per scan
Executed
per scan
Executed only once
Executed
only once
CALL
CALLP
Subroutine execution
command
When the ON/OFF time is shorter than the scan time:
When the ON/OFF time is longer than the scan time:
X0
M0
X0
M0
Scan time
Scan time
CALL P0
FEND
X000
M9036
PLS P0
RET
29
30
35
P0
0

Table of Contents

Other manuals for Mitsubishi MELSEC-A series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC-A series and is the answer not in the manual?

Mitsubishi MELSEC-A series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC-A series
CategoryController
LanguageEnglish

Related product manuals