9 LONG-TERM STORAGE
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
183
Pub. No. K29001-00320 Revision: 1
9 Apply engine oil on the valve
mechanisms of all the cylinder
heads.
• Tool: Oiler, oil jug, and others.
Fig. 9-2 Engine Oil - Apply (Valve Mechanism)
10 Install the rocker covers onto all the
cylinder heads.
• Tool: Wrench
Fig. 9-3 Rocker Cover - Install
â–  Restart
1 Pull the manual stop lever in the
direction to stop and hold the
position, and crank the engine for
approx. 10 seconds using the
starter.
Fig. 9-4 Restart after Storing
• The location of the manual stop lever
varies depending on the specification
of the engine. Refer to
"Protection
System - Location" (→ Page 82).
2 Pause for about 1 minute.
3 Repeat the operation of Step 1 and 2
for 2 or 3 times.
4 After starting the engine, check that
the engine oil pressure rises with a
pressure gauge.
5 Conduct a warm-up operation
"Warm-up Operation" (→ Page 99) for
a sufficient duration to fully lubricate
all the components.
6 Apply load and increase the engine
speed to the rated speed.
Storing Engine in Operable
Condition
Perform maintenance operation "Maintenance
Operation" (→ Page 103) once a month.
䣕䣖䣑䣒
䣕䣖䣑䣒䣕䣖䣑䣒

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi S16R Series and is the answer not in the manual?

Mitsubishi S16R Series Specifications

General IconGeneral
BrandMitsubishi
ModelS16R Series
CategoryEngine
LanguageEnglish

Related product manuals