Page #102 background image
'18 • SRK-T-234
-
100
-
CAUTION
-
HIGH VOLTAGE
High voltage is produced in the control box. Don't touch
electrical parts in the control box for 5 minutes after the
unit is stopped.
Inspection of electronic
expansion valve
See page 102.
Inspection of resistance valve of sensor
Remove the connector and check the resistance valve.
See the section of sensor characteristics on page 92.
Power source and serial signal inspection
L to N : AC220/230/240V
1 to 2/N : AC220/230/240V
2/N to 3 : Normal if the voltage oscillates between
DC0 and approx. 20V
Inspection power transistor
Remove the fasten terminal and test
output voltage.
Inspection of outdoor fan motor
See page 102.
Check point of outdoor unit
Color
Color symbol
OR
Mark
BrownBR
YellowGreenYG
BlackBK
BlueBL
WhiteWH
YellowYE
RedRD
Orange
Display Voltage range
Voltage check in PCB
The normal range is as follows.
DC280V DC230V - DC310V
DC220V DC218V - DC222V
DC213V DC212V - DC214V
DC215V DC214V - DC216V
DC225V DC224V - DC226V
DC 2.5V DC 2.3V - DC
2
2.5V
M
T2
BK
WH
RD
V WU
M
CNTH
CNEEV
CNFAN
1 2 3 4 6
t
L
OR
T1
YE
2 2 2
TH2 TH3 TH4
EEV
FMo
t
t
MS
CM
3
WH
OR
BR
RD
BL
N L
250V 15A
2
1
N
3
YG
20S
Outdoor unit
S.IN
R.IN
C-2
RD
WH
BK
BK
CN20S
TB1
TERMINAL
BLOCK
Power source
1 Phase
AC200-240V 50Hz
Indoor
unit
(12) Outdoor unit inspection points
Models SRC20ZSX-W, 25ZSX-W, 35ZSX-W

Table of Contents