EasyManuals Logo
Home>Mitsubishi>Air Conditioner>SRK20ZSX-W

Mitsubishi SRK20ZSX-W User Manual

Mitsubishi SRK20ZSX-W
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
'18 • SRK-T-234
-
25
-
(2) Outdoor units
Models SRC20ZSX-W, 25ZSX-W, 35ZSX-W
RWC000Z305
2.0mm
2
x 3 22 1.5mm
2
x 4
9
[
]
2
N
. For an installation
YellowGreen
*
MAX running current Power cable
wire size x number*A
Power cable length
m
Connecting cable
wire size x number*
BK Black
Mark Color
RD Red
WH White
OR Orange
YE Yellow
YG
YellowGreen
BK
WH
RD
V
W
U
PCB ASSY PCB1
M
MS
TRANSISTOR
POWER
POWER
T 1A L 250V
W
V
UP
N
CNTH CNEEV
CNFAN
3
+
S.IN
R.IN
G1
250V 15A
F7
C-2
RD
CN20S
WH
WH
F 3.15A L 250V
F1
BK
BK
WH
YG
YG
RD
G2
20S
SWITCHING
CIRCUIT
+
F3
FILTER
NOISE
L 1
N 2
3
YG
EEV
L
FMo
CM
TH4TH2 TH3
2 2
4
22
BK
3
SIGNAL WIRE
EARTH WIRE
M
1
3
250V 20A
F2
YE OR
T1 T2
CIRCUIT
PAM
250V 10A
F4
t
t
t
t
t
TB1
BLOCK
TERMINAL
TH4 Discharge pipe temp. sensor
TH3 Outdoor air temp. sensor
TH2 Heat exchanger sensor
L Reactor
FMo Fan motor
EEV Electric expansion valvecoil
CM Compressor motor
CNTH
CNFAN
CNEEV
CN20S Connector
20S 4-way valvecoil
Item Description
STACK4
DIODE
STACK2
DIODE
STACK1
DIODE
1 Phase
220V 60Hz
Color marks
Meaning of marks

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SRK20ZSX-W and is the answer not in the manual?

Mitsubishi SRK20ZSX-W Specifications

General IconGeneral
BrandMitsubishi
ModelSRK20ZSX-W
CategoryAir Conditioner
LanguageEnglish

Related product manuals