'18 • SRK-T-234
-
69
-
'09•SRK-DB-087D
(b)
Sleep timer operation
(11)
Timer operation
(a)
Comfort start-up (ON timer operation)
(c)
OFF timer operation
(14)
Air flow range setting
(a)
Setting
(i) If the air-conditioner is running, press the ON/OFF button to stop.
(ii)
Press the AIR FLOW U/D (UP/DOWN) button and the
AIR FLOW L/R (LEFT/RIGHT) button together for 5 seconds
or more.
(iii)
Setting the air flow range.
(iv)
Press the ON/OFF button.
Air flow range Air flow rangeAir flow range
(Left end installation) (Center installation) (Right end installation)
(Center installation)
L/R
L/R
(Right end installation) (Left end installation)
The unit starts the operation 5 to 60 minutes earlier so that the room can approach optimum temperature at ON timer.
The OFF timer can be set at a specific time (in 10-minute units) within a 24-hour period.
(d)
Weekly timer operation
Up to 4 programs with timer operation (ON timer / OFF timer) are available for each day of the week.
Take the air-conditioner location into account and adjust the left/right air flow range to maximize air-conditioning.
display
( i ), (
iv
)
(
ii
), (
iii
)
(
ii
)
MENU
'09•SRK-DB-087D
(b)
Sleep timer operation
(11)
Timer operation
(a)
Comfort start-up (ON timer operation)
(c)
OFF timer operation
(14)
Air flow range setting
(a)
Setting
(i) If the air-conditioner is running, press the ON/OFF button to stop.
(ii)
Press the AIR FLOW U/D (UP/DOWN) button and the
AIR FLOW L/R (LEFT/RIGHT) button together for 5 seconds
or more.
(iii)
Setting the air flow range.
(iv)
Press the ON/OFF button.
Air flow range Air flow rangeAir flow range
(Left end installation) (Center installation) (Right end installation)
(Center installation)
L/R
L/R
(Right end installation) (Left end installation)
The unit starts the operation 5 to 60 minutes earlier so that the room can approach optimum temperature at ON timer.
The OFF timer can be set at a specific time (in 10-minute units) within a 24-hour period.
(d)
Weekly timer operation
Up to 4 programs with timer operation (ON timer / OFF timer) are available for each day of the week.
Take the air-conditioner location into account and adjust the left/right air flow range to maximize air-conditioning.
display
(12)
Silent operation
When the silent operation is set, the unit operates by dropping the outdoor fan speed and the compressor speed.
(13)
Night setback operation
When the night setback operation is set, the heating operation starts with the setting temperature at 10
.
Outdoor fan speed
(Upper limit)
Compressor speed
(Upper limit)
Cooling Heating Cooling Heating Cooling Heating
SRK20 SRK25 SRK35
4th speed
18 rps
4th speed
26 rps
4th speed
24 rps
4th speed
28 rps
5th speed
36 rps
6th speed
44 rps
Cooling Heating Cooling Heating
SRK50 SRK60
5th speed
43 rps
5th speed
48 rps
5th speed
43 rps
5th speed
48 rps

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SRK20ZSX-W and is the answer not in the manual?

Mitsubishi SRK20ZSX-W Specifications

General IconGeneral
BrandMitsubishi
ModelSRK20ZSX-W
CategoryAir Conditioner
LanguageEnglish

Related product manuals