© National Instruments | 2-5
M Series User Manual
68-Pin Cables
Cabling options differ between the 68-pin PCI/PCI Express/PXI/PXI Express devices and
modules and USB Mass Termination devices.
PCI/PCI Express/PXI/PXI Express Device/Module 68-Pin Cables
You can use the following cables with PCI, PCI Express, PXI, and PXI Express M Series devices
and modules:
• SHC68-68-EPM
1
—(Recommended) High-performance shielded cable designed for
M/X Series devices. It has individual bundles separating analog and digital signals. Each
differential analog input channel is routed on an individually shielded twisted pair of wires.
Analog outputs are also individually shielded.
• SHC68-68—(Recommended) Lower-cost shielded cable with 34 twisted pairs of wire. The
cable is recommended for PCI/PXI-6225/6255 Connector 1.
Note You must use the SHC68-68 cable on Connector 1 of PCI/PXI-6225/6255
devices and modules. The SHC68-68-EPM cable can be used on Connector 0 of all
M Series PCI, PCI Express, PXI, and PXI Express devices and modules, and on
Connector 1 of NI PCI/PCIe/PXI/PXI-6224/6229/6254/6259/6284/6289 devices and
modules.
• RC68-68—Highly-flexible unshielded ribbon cable.
USB Mass Termination Device 68-Pin Cables
You can use the following cables with USB devices with mass termination connectors:
• SH68-68-EPM
2
—(Recommended) High-performance cable with individual bundles
separating analog and digital signals. Each differential analog input channel is routed on an
individually shielded twisted pair of wires. Analog outputs are also individually shielded.
• SH68-68-S—(Recommended) Shielded cable with 34 twisted pairs of wire. Each
differential analog input channel on Connector 1 is routed on a twisted pair on the
SH68-68-S cable. The cable is recommended for USB-6225/6255 Mass Termination
Connector 1.
Note You must use the SH68-68-S cable on Connector 1 of USB-6225/6255
Mass Termination devices. The SH68-68-EPM cable can be used on Connector 0 of
all M Series USB Mass Termination devices, and on Connector 1 of
USB-6229/6259/6289 devices and modules.
• R68-68—Highly-flexible unshielded ribbon cable.
1
NI recommends that you use the SHC68-68-EPM cable; however, an SHC68-68-EP cable works with
PCI/PCI Express/PXI/PXI Express devices and modules.
2
NI recommends that you use the SH68-68-EPM cable; however, an SH68-68-EP cable will work with
USB Mass Termination devices.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments 622 Series and is the answer not in the manual?

National Instruments 622 Series Specifications

General IconGeneral
BrandNational Instruments
Model622 Series
CategoryI/O Systems
LanguageEnglish

Related product manuals