EasyManuals Logo
Home>National Instruments>I/O Systems>NI 6323

National Instruments NI 6323 User Manual

National Instruments NI 6323
299 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #115 background imageLoading...
Page #115 background image
Chapter 5 Analog Output
X Series User Manual 5-6 ni.com
Figure 5-2. Analog Output Connections
Analog Output Timing Signals
Figure 5-3 summarizes all of the timing options provided by the analog
output timing engine.
Figure 5-3. Analog Output Timing Options
X Series devices feature the following analog output (waveform
generation) timing signals:
• AO Start Trigger Signal
*
• AO Pause Trigger Signal
*
Load
Load
V OUT
V OUT
+
–
+
–
AO GND
AO 3
Analog Output Channels
AO 2
Channel 3
Connector 1 (AI 16– 31)
Channel 2
X Series Device
Load
Load
V OUT
V OUT
+
–
+
–
AO GND
AO 1
Analog Output Channels
X Series Device
AO 0
Channel 1
Channel 0
Connector 0 (AI 0 –15)
PFI, RTSI
PXI_STA R
Analog Comparison
Event
20 MHz Timebase
100 kHz Timebase
PXI_CLK10
Programmable
Clock
Divider
AO Sample Clock
Timebase
PFI, RTSI
PXI_STA R
Analog Comparison Event
Ctr n Internal Output
100 MHz Timebase
DSTAR <A..B>
DSTAR <A..B>
AO Sample Clock
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments NI 6323 and is the answer not in the manual?

National Instruments NI 6323 Specifications

General IconGeneral
BrandNational Instruments
ModelNI 6323
CategoryI/O Systems
LanguageEnglish

Related product manuals