Page 54/90 GEO M12 HARDWARE SETUP PROCEDURE
6.4.4 MSUB18 flown with Touring Bumper
Required items
- 1 or 2 hoists (not provided).
- 1 x VNT-BUMPM12
- 1 x VNT-EXBARM12 to fly on a single rigging point
IMPORTANT
When flying MSUB18 cluster, VNT-BUMPM12 must be set at 0°
- If cluster is flown from 2 points, bumper must be maintained horizontal in its definitive
position as well as when lifting or lowering the cluster
- If cluster is flown from a single point, extension bar must be used and hoist connected
to “G” position
IMPORTANT
Maximum MSUB18 quantity for flown vertical cluster with VNT-BUMPM12 is 8.
Please check NS-1 for mechanical Safety Working Load and acoustic computations.
IMPORTANT
Motor hoist must be rated to support entire cluster weight. Please check configuration
in NS-1 for proper motor hoist rating