30 – ENGLISH
TECHNICAL SPECIFICATIONS
12
12 TECHNICAL SPECIFICATIONS
l
All technical specications stated in this section refer to an ambient temperature of 20°C (± 5°C). Nice S.p.A.
reserves the right to apply modications to the product at any time when deemed necessary, without altering
its functions and intended use.
Table 19
TECHNICAL SPECIFICATIONS
Description Technical specication
Product type
Electromechanical gearmotor for sectional doors
Power supply 230Va (+10% -15%) 50/60Hz
Maximum current draw (A)
1,5
Nominal current draw (A)
1
Maximum torque (Nm)
50
Rated torque (Nm)
30
Maximum power consumption (W)
350
Nominal power consumption (W)
220
Maximum speed (rpm)
30
Nominal speed (rpm)
18
Static holding torque (Nm)
130
Protection rating (IP)
40
Operating temperature (min/max °C)
-20°C ÷ 50°C
Maximum door surface area (m2)
20
Maximum door height (m)
5
Insulation class
I
Durability
Estimated between 40,000 and 120,000 cycles, depending on the
conditions specied in the “Product durability” paragraph
Cycles per hour at the rated torque – for doors with 3 m
height (cycles/hour)
15
Dimensions (mm)
115x375x300
Weight (kg)
10,5
Hole (mm)
25,5
Emergency power supply
Yes (PS124 battery)
Courtesy light
12V/21W BA15S tting
Warning light output[Note 1]
For 1 LUCYB warning light; MLB or MLBT (12 V, 21 W lamp)
BLUEBUS output
One output with maximum load of 12 BlueBUS units
STOP input
For normally closed or normally open contacts or for 8.2 kΩ xed
resistor contacts with self-learning (any variation from the memorised
status triggers the STOP command)
Sbs input[Note 2]
For normally open contacts (closing of the contact triggers the STEP-
BY-STEP command)
OPEN input[Note 2]
For normally open contacts (closing of the contact triggers the “OPEN”
command)
CLOSE input[Note 2]
For normally open contacts (closing of the contact triggers the CLOSE
command)
Radio ANTENNA input
52 Ω for RG58-type cable or similar
Programming input
For 1 OVIEW programmer with 4-pin telephone cable and RJ14
connector
Radio connector
SM connector for SMXI, SMXIS or OXI receivers
Programmable functions
8 ON-OFF and 8 adjustable functions
Self-learning functions
Self-learning of the devices connected to the BlueBus output
Self-learning of the type of “STOP” device (Normally Open, Normally
Closed contact or 8.2 kΩ resistor)
Self-learning of the gate length and calculation of the deceleration and
partial opening points
Use in highly acid, saline or potentially explosive
atmosphere
No